\documentclass{../bkm} \begin{document} \heading{FIS}{Drehstrommotoren}{27.2.2023} \section{Berechnungen} \begin{equation} \begin{split} U &= 400V \\ I &= 0.67A \\ \cos(\varphi) &= 0.85 \\ f &= 50Hz \\ \\ \varphi &= \arccos(\cos(\varphi)) \\ \varphi &= \arccos(0.85) \\ \varphi &= 1.\bar{55} \\ \\ P &= U * I * \cos(\varphi) * \sqrt{3} \\ P &= 400V * 0.67A * 0.85 * \sqrt{3} \\ P &= 394.561W \\ \\ Q_L &= U * I * \sin(\varphi) * \sqrt{3} \\ Q_L &= 400V * 0.67A * \sin(1.55)) * \sqrt{3} \\ Q_L &= 12.556W \\ \\ S &= U * I * \sqrt{3} \\ S &= 400V * 0.67A * \sqrt{3} \\ S &= 464.189W \\ \\ Z &= \frac{U}{I} \\ Z &= \frac{400V}{0.67A} \\ Z &= 597.014\Omega \\ \\ R &= Z * \cos(\varphi) \\ R &= 597.014\Omega * 0.85 \\ R &= 507.461\Omega \\ \\ X_L &= \sin(31.79) * 597.01\Omega \\ X_L &= 314.509\Omega \\ L &= \frac{X_L}{2*\pi*f} \\ L &= \frac{314.509\Omega}{2*\pi*50Hz} \\ L &= 1.001H \end{split} \end{equation} \section{Vertretungsaufgaben} \ddate{13.3.2023} \subsection{Aufgabe 1} Gegeben: \begin{equation} \begin{split} R_s^Y &= 38\Omega \\ U &= 400V \end{split} \end{equation} \subsubsection{a)} \begin{equation} \begin{split} U_s &= \frac{U}{\sqrt{3}} \\ U_s &= \frac{400V}{\sqrt{3}} \\ U_s &\simeq 230V \end{split} \end{equation} \subsubsection{b)} \begin{equation} \begin{split} I_s &= \frac{U_s}{R_s} \\ I_s &= \frac{230V}{38\Omega} \\ I_s &= 6.052A \end{split} \end{equation} \subsubsection{c)} \begin{equation} I = I_s = 6.052A \end{equation} \subsection{Aufgabe 2} Gegeben: \begin{equation} \begin{split} R_s^Y &= 32\Omega \\ I_{s1} &= 7.2A \end{split} \end{equation} \\\\ Falscher Ansatz: Könnte auch 690V Netz sein. \subsubsection{a)} \begin{equation} \begin{split} U_s &= \frac{U}{\sqrt{3}} \\ U_s &= \frac{400V}{\sqrt{3}} \\ U_s &\simeq 230V \end{split} \end{equation} falscher weg \subsubsection{b)} \begin{equation} \begin{split} U_l &= (2*R_s)*(\frac{I_s}{2}) \\ U_l &= (2*32\Omega)*(\frac{7.2A}{2}) \\ U_l &= 64\Omega*3.6A \\ U_l &\simeq 230V \end{split} \end{equation} falsch \subsection{Aufgabe 3} \begin{equation} \begin{split} U^Y &= 400V \\ I_s &= 10.3A \\ \\ U_s &= \frac{U}{\sqrt{3}} = 230V \\ \\ R_s &= \frac{U_s}{I_s} \\ R_s &= \frac{230V}{10.3A} \\ R_s &= 22.33\Omega \end{split} \end{equation} \subsection{Aufgabe 4} \begin{equation} \begin{split} U^Y &= 400V \\ I_s &= 17.3A \\ \\ U_s &= \frac{U}{\sqrt{3}} = 230V \\ \\ R_s &= \frac{U_s}{I_s} \\ R_s &= \frac{230V}{17.3A} \\ R_s &= 13.295\Omega \end{split} \end{equation} \subsection{Aufgabe 5} \begin{equation} \begin{split} U^Y &= 400V \\ f &= 50Hz \\ I_s &= 3.5A \\ \\ U_s &\simeq 230V \\ X_C &= \frac{U_s}{I_s} \\ X_R &= \frac{1}{2*pi*f*XC} \\ \\ c &= ? \end{split} \end{equation} \subsection{Aufgabe 6} Gegeben: \begin{equation} \begin{split} U_l^Y &= 400V \\ f &= 50Hz \\ c &= 22\mu F \end{split} \end{equation} \subsubsection{b)} \begin{equation} \begin{split} X_C &= \frac{1}{2*\pi*f*C} \\ X_C &= \frac{1}{2*\pi*50Hz*22\mu F} \\ X_C &= 144.68\Omega \\ \\ I_l &= \frac{U_l}{X_C} \\ I_l &= \frac{400V}{144.68\Omega} \\ I_l &= 2.764A \end{split} \end{equation} \subsubsection{a)} \begin{equation} \begin{split} I_s &= \frac{I_l}{\sqrt{3}} \\ I_s &= \frac{2.764A}{\sqrt{3}} \\ I_s &= 1.595A \end{split} \end{equation} \subsection{Aufgabe 7} Gegeben: \begin{equation} \begin{split} U^Y &= 400V \\ I_s &= 12A \end{split} \end{equation} \subsubsection{a)} \begin{equation} \begin{split} U_s &= \frac{U}{\sqrt{3}} = 230V \\ \\ R_s &= \frac{U_s}{I_s} \\ R_s &= \frac{230V}{12A} \\ R_s &= 19.667\Omega \end{split} \end{equation} \subsubsection{b)} \begin{equation} \begin{split} R_{s_2} &= 15\Omega \\ \\ I_{s_2} &= \frac{U_s}{R_s} \\ I_{s_2} &= \frac{230V}{15\Omega} \\ I_{s_2} &= 15.333A \end{split} \end{equation} \subsection{Aufgabe 8} Gegeben: \begin{equation} \begin{split} U_l^Y &= 400V \\ R_l &= 48\Omega \\ \\ I_l &= \frac{U_l}{R_l} \\ I_l &= \frac{400V}{48\Omega} \\ I_l &= 8.33A \\ \\ P &= U_l*I_l \\ P &= 400V*8.33A \\ P &= 3.332kW \end{split} \end{equation} falsch; falscher weg; $I_{str} = U_{str}:R_{str}$ \ddate{12.6.2023} \section{7.11.3} \subsection{Aufgabe 1} Gegeben \begin{equation} \begin{split} R &= 50\Omega \\ U^Y &= 400V \end{split} \end{equation} \subsubsection{Teilaufgabe a)} \begin{equation} \begin{split} U_s &= [...] 230V \\ \\ I_s &= \frac{U_s}{R_s} \\ I_s &= \frac{230V}{50\Omega} \\ I_s &= 4.6A \end{split} \end{equation} \subsubsection{Teilaufgabe b)} \begin{equation} I_l = I_s = 4.6A \end{equation} \subsubsection{Teilaufgabe c)} \begin{equation} \begin{split} P_s &= U_s * I_s^2 \\ P_s &= 230V * 4.6A^2 \\ P_s &= 1.066kW \end{split} \end{equation} \subsubsection{Teilaufgabe d)} \begin{equation} \begin{split} P_g &= P_s * 3 \\ P_g &= 1.066kW * 3 \\ P_g &= 3.198kW \\ \\ P_g &= U_l * I_l * \sqrt{3} * \cos{(\varphi)} \end{split} \end{equation} Die Formel ist anwendbar auf $Y$ und $\Delta$ bei symmetrischer Last \subsection{Aufgabe 2} Gegeben: \begin{equation} \begin{split} U^Y_l &= 400V \\ P_g &= 3966W \end{split} \end{equation} \subsubsection{Teilaufgabe a)} \begin{equation} \begin{split} P_s &= \frac{P_g}{3} \\ P_s &= \frac{3966W}{3} \\ P_s &= 1322W \end{split} \end{equation} \subsection{Aufgabe 3} \subsection{Aufgabe 4} \section{MEHR AUFGABEN WOOHOO} \subsection{Aufgabe 1} Gegeben: \begin{equation} \begin{split} I_1 &= 2A \\ I_2 &= 3A \\ I_3 &= 5A \end{split} \end{equation} Lösung: $2.6A$ \\ \img{Geometrie Drehstrom 001.png}{Geometrie Drehstrom 001} \subsection{Aufgabe 2} Gegeben: \begin{equation} \begin{split} R_1 &= 20\Omega \\ R_2 &= 30\Omega \\ R_3 &= 40\Omega \end{split} \end{equation} \subsubsection{Teilaufgabe a)} \begin{equation} \begin{split} U_s &\simeq 230V \\ I_{s_n} &= \frac{U_s}{R_n} \\ \\ I_{s_1} &= 11.5A \\ I_{s_2} &= 7.66A \\ I_{s_3} &= 5.75A \end{split} \end{equation} \subsubsection{Teilaufgabe b)} Lösung: $5.1A$ \\ \img{Geometrie Drehstrom 002.png}{Geometrie Drehstrom 002} \subsubsection{Teilaufgabe c)} ??? \subsection{Aufgabe 3} bild im buch lol \subsubsection{Teilaufgabe a)} \subsubsection{Teilaufgabe b)} \subsubsection{Teilaufgabe c) (zeichnerisch)} \end{document}